LIQUID COOLING SYSTEM 430kWh outdoor battery storage cabinet suppliedby BNYPOWER can provide additional power to thegrid when needed.In combination with an energystorage system, the load pressure on the transformercan be reduced, thus postponing or avoiding the need for the transformer's capacity expansion.
BP430 BP215 BP200
DC Parameter Rated Power 430kWh Rated Voltage 768V Voltage Range 648~864V Max. (DC) Current 340A Rated (DC) Current 280A Number Modules 10
Parameter for Communication Rated Power 215kW Rated Grid Voltage 400V Allow Grid Voltage 360-440V Rated (AC) Current 312A Power Factor & Adjustable Range >0.99, -1~1 Rated Grid Frequency 50Hz/60Hz Methods of Communication Access 3-Phase 4-Wire System Max. Number of Units in Parallel Off-Grid 10
System Parameters Dimensions 1870×2519×1500mm Weight 4200kg Protection Level IP55 Operating Temperature -30~50°C System Efficiency ≥89% Cooling Method Liquid Cooling Highest Working Altitude 5,000m (>2,000 Reduce usage as needed ) External Communication Methods RS485 / CAN / Ethernet / 4G Life Cycle ≥8000 (@25°C, 100%DOD, 0.5P EOL ≥70%) Remote Monitoring EMS, APP Operation Mode Support & Network / Switching Between Networks Cabinet Corrosion Resistance Level C3 System Design Lifetime ≥10year
DC Parameter Rated Power 215kWh Rated Voltage 768V Voltage Range 648~864V Max. (DC) Current 170A Rated (DC) Current 140A Number Modules 15
Parameter for Communication Rated Power 107.5kW Rated Grid Voltage 400V Allow Grid Voltage 360~440V Rated (AC) Current 156A Power Factor & Adjustable Range >0.99, -1~1 Rated Grid Frequency 50Hz/60Hz Methods of Communication Access 3-Phase 4-Wire System Max. Number of Units in Parallel Off-Grid 10
System Parameters Dimensions 1600×2400×1200mm Weight 2600kg Protection Level IP55 Operating Temperature -30~50°C System Efficiency ≥88% Cooling Method Cold Wind Highest Working Altitude 5,000m (>2,000 Reduce usage as needed ) External Communication Methods RS485 / CAN / Ethernet / 4G Life Cycle ≥8000 (@25°C, 100%DOD, 0.5P EOL ≥70%) Remote Monitoring EMS, APP Operation Mode Support & Network / Switching Between Networks Cabinet Corrosion Resistance Level C3 System Design Lifetime ≥10year
DC Parameter Rated Power 200kWh Rated Voltage 716.8V Voltage Range 627.2~806.4V Max. (DC) Current 165A Rated (DC) Current 140A Number Modules 14
Parameter for Communication Rated Power 100kW Rated Grid Voltage 400V Allow Grid Voltage 360~440V Rated (AC) Current 145A Power Factor & Adjustable Range >0.99, -1~1 Rated Grid Frequency 50Hz/60Hz Methods of Communication Access 3-Phase 4-Wire System Max. Number of Units in Parallel Off-Grid 10
System Parameters Dimensions 1600×2400×1200mm Weight 2550kg Protection Level IP55 Operating Temperature -30~50°C System Efficiency ≥88% Cooling Method Liquid Cooling Highest Working Altitude 5,000m (>2,000 Reduce usage as needed ) External Communication Methods RS485 / CAN / Ethernet / 4G Life Cycle ≥8000 (@25°C, 100%DOD, 0.5P EOL ≥70%) Remote Monitoring EMS, APP Operation Mode Support & Network / Switching Between Networks Cabinet Corrosion Resistance Level C3 System Design Lifetime ≥10year